Workshop on the Applications of 4D-STEM; 16. - 17. 9.

Advanced Micro‑CT engineered for Insight

Speed, clarity, and adaptability - designed for researchers pushing boundaries in materials, life sciences, and beyond. Tescan’s micro‑CT solutions deliver fast, non‑destructive 3D and real‑time 4D imaging, from sub‑micron resolution with UniTOM HR to high throughput and scale flexibility with UniTOM XL. Coupled with innovations like Spectral CT for 3D chemical mapping and our dynamic tools for in‑situ experiments, our systems empower you to visualize structure, composition, and processes.

Tescan UniTOM HR

High-resolution micro-CT for sub-micron imaging and dynamic 4D in-situ material testing.

UniTOM HR combines sub-600 nm spatial resolution with high-speed time-resolved 3D imaging in a single instrument. Built for advanced R&D, it enables visualization of structural evolution under load, temperature, or environmental conditions in real time, across a range of sample sizes.

Key benefits

  • Captures microstructural evolution with 4D imaging and sub-micron resolution—ideal for crack propagation, swelling, and degradation studies.
  • Simplifies dynamic testing setups with flexible stages, radiation-safe ports, and real-time visualization tools.
  • Accelerates insight with automated batch workflows, rapid reconstruction, and seamless macro-to-micro imaging.
MICRO_UniTOM_HR_1-2
Tescan UniTOM HR
Tescan UniTOM XL

Large-volume, high-throughput micro-CT system for static and dynamic 3D imaging across full-size components.

UniTOM XL offers non-destructive 3D and 4D imaging of large and heavy samples—up to 1 meter tall—while maintaining fine internal resolution. With multiscale zoom, high-flux source, and in-situ capabilities, it supports composite inspection, QA, and process monitoring.

Key benefits

  • Accommodates samples up to 60 cm diameter and 100 cm tall—ideal for assembled devices, porous structures, or large composites.
  • Boosts lab productivity with automation-ready workflows, high-speed detectors, and volume-of-interest batch scanning.
  • Enables real-time 4D imaging of internal material behavior under load, temperature, or humidity—minimizing guesswork in failure analysis.
MICRO_UniTOM_XL_1-2
Tescan UniTOM XL
Tescan DynaTOM

Dynamic micro‑CT engineered for uninterrupted 4D in‑situ experimentation.

TESCAN DynaTOM is the world’s first lab-based micro‑CT system purpose-built for complex in‑situ studies. Its gantry-style architecture allows continuous, high‑temporal‑resolution scanning (as fast as ~7.5 seconds per rotation at 12.5 µm voxel size), while staying compatible with complex test rigs and dynamic process setups.

Key benefits

  • Captures real-time structural evolution—such as multiphase flow, crack propagation, or material deformation—with uninterrupted 4D scanning and in-situ integration tools.
  • Handles delicate dynamic setups using a fixed sample, moving-source/detector gantry design to avoid sample movement or cable interference.
  • Accelerates insight with high-throughput, time-lapse reconstruction and intuitive 4D visualization software.
MICRO_DynaTOM_MB_1_v2-2
Tescan DynaTOM
Tescan Spectral CT (Add-on for UniTOM XL)

Structural + chemical insight in one: non-destructive spectral micro‑CT imaging.

TESCAN Spectral CT brings true spectral imaging to micro‑CT by capturing the full X‑ray spectrum before and after sample interaction—adding chemical and compositional contrast to standard 3D structural imaging.

Key benefits

  • Enables in-sample, non-destructive elemental identification—such as precious metals, polymer differentiation, or tissue contrast—using k-edge detection and multi-energy analysis during a single scan.
  • Provides unmatched contrast in low-differentiation applications, enhancing analysis where traditional micro-CT fails.
  • Seamlessly integrates with UniTOM XL with one-click switching, rich spectral software suite, and compatibility with existing workflows.
MICRO_UniTOM_XL_1 (1)-1
Tescan Spectral CT

GET IN Touch

Explore the tool that helps you get answers

Tescan instruments are built to solve your research challenges - fast.
Let’s find the right solution together. 

Let’s find the right fit for your research

Talk to a Tescan expert about your goals - we’ll help you pinpoint the system and workflow that move your work forward.

map

Where can
you find us:

Tescan Brno
Libušina třída 21
623 00 Brno
Czech Republic

info@tescan.com