WEBINAR | From Infrastructure to Impact: EM & Micro-CT in Materials Core Facilities

The Most Universal FIB-SEM: High-Throughput 3D Characterization and Ga+-Free high Quality Sample Preparation in the single Plasma FIB-SEM Platform

Tescan AMBER X 2

AMBER X
AMBER X

TESCAN AMBER X 2 combines Mistral™ Plasma FIB and the field-free BrightBeam™ UHR SEM so you can achieve Ga+-free, low-damage, fully automated TEM lamella preparation using TEM AutoPrep Pro™ while maintain large 2D/3D multimodal characterization sample throughput.

  • A unified platform for both precision TEM prep and large-volume 3D characterization

  • Ga+-free TEM lamella preparation with minimal amorphization damage

  • Fully automated (TEM AutoPrep Pro™) workflow for consistent and accessible sample preparation

  • High-throughput 3D analysis with stable beam performance at all FIB and SEM currents

  • Field-free BrightBeam™ UHR SEM for magnetic, non-conductive, and sensitive materials

  • Energy-filtered electron signals for enhanced surface and phase contrast of the samples

Where Tescan AMBER X 2

makes the difference

High-Precision, Large-Area Cross Sections

Generate high-quality cross sections at high milling currents with Mistral™ Plasma FIB, combining rapid material removal with nanometer-scale accuracy for both large-volume and fine-detail workflows.

Ultra-High-Resolution Nanocharacterization

Image and analyze the widest range of materials with the BrightBeam™ field-free UHR SEM, delivering stable low-energy performance ideal for magnetic, non-conductive, and beam-sensitive samples.

Ga+-Free TEM Sample Preparation

Prepare clean, damage-reduced TEM lamellae using Xe+ plasma FIB—achieving the precision of Ga+ workflows without the risk of gallium contamination.

Fast, Artifact-Reduced Large-Volume 3D Analysis

Accelerate large-area cross-sectioning and 3D tomography up to 1 mm while maintaining superior surface quality. The TESCAN Rocking Stage minimizes curtaining, even in porous, brittle, or highly heterogeneous materials.

Multimodal 3D Chemical and Structural Insight

Acquire EDS, EBSD, and ToF-SIMS data within a single FIB-SEM tomography workflow to reveal morphology, crystallography, elemental composition, and isotopic chemistry in true 3D.

Automated TEM Workflow Acceleration

Leverage TEM AutoPrep Pro™ for guided or fully automated lamella preparation. Region selection, geometry setup, and final polishing are streamlined, increasing reproducibility and freeing instrument time for imaging and analysis.

Scalable, User-Friendly Operation for Any Lab

Operate confidently with guided automation, intuitive controls, and modular Tescan Essence™ software—supporting both expert and novice users in high-throughput, multi-user environments.

Tescan AMBER X2 Applications

_ Application area icon
Tescan AMBER X2 in Materials Science

Gain the detail you need to understand how materials behave, from nanoscale structures to millimeter-scale volumes.

  • Comprehensive 3D characterization for microstructural studies
  • Automated TEM lamella preparation with TEM AutoPrep Pro™
  • Correlative multimodal analysis combining EDS, EBSD and ToF-SIMS
  • Large-volume milling for full-field reconstruction and structural insight

AMBER X2 gives materials scientists a reliable way to study metals, ceramics, polymers and composites with both precision and scale. Its Xe plasma FIB and field-free SEM architecture support high-resolution imaging without unnecessary beam damage. This helpa you explore structure–property relationships and track material changes under load, heat or environmental exposure.

Application area=BT-1
Tescan AMBER X2 in Energy and Batteries

Get a clearer view of electrode architecture, interface behavior, and the mechanisms that drive degradation.

  • Damage-free plasma FIB-SEM workflows for electrodes and interfaces
  • Cross-sectioning and 3D reconstruction of electrodes and solid-state architectures
  • Correlative EDS and ToF-SIMS for chemical and structural gradients
  • Safe, contamination-free milling of lithium-containing and beam-sensitive materials

AMBER X2 helps battery researchers examine internal structures with clarity, from active material morphology to subtle interface changes. Its high-throughput plasma FIB and multimodal analysis tools reveal degradation pathways, lithium distribution patterns, and stability issues. This gives you the insight needed to refine materials and design more reliable energy-storage systems.

_ Application area icon (3)
Tescan AMBER X2 in Semiconductors

Uncover the electrical and structural details of today’s most advanced devices

Uncover the electrical and structural details of today’s most advanced devices with Tescan AMBER X 2 Plasma FIB-SEM. Purpose-built for semiconductor applications, AMBER X 2 combines Xe plasma FIB with proprietary Nanoflat, Chase, and C-Maze chemistries to deliver uniform, artifact-free delayering at sub-10 nm nodes.

The system ensures you have reproducible workflows across logic, memory, and I/O regions, supporting electrical fault isolation, failure analysis, and transistor-level probing.

  • Perform artifact-free delayering with Nanoflat, Chase, and C-Maze chemistries
  • Protect device integrity using low-kV Xe Plasma FIB milling
  • Control every step with end-point detection and live monitoring
  • Integrate delayering with in situ nanoprobing in a single workflow
  • Deprocess I/O and thick metal layers using low angle polishing

Resolve critical details with BrightBeam™ UHR SEM imaging at sub-500 eV

_ Application area icon (1)
Tescan AMBER X2 in Life Sciences

Work confidently across cryogenic and room-temperature workflows, whether you're studying ultrastructure or preparing samples for high-resolution imaging.

  • Large-volume 3D FIB-SEM tomography of hard biological materials, including bone, shell and dental tissue
  • High-quality cryo lamella preparation with MISTRAL™ Plasma FIB for fast rough milling and precise low-energy polishing
  • Integrated CLEM workflows with METEOR 2.0 for accurate ROI targeting
  • Built-in cryo nanomanipulator for temperature-controlled, reliable lift-out
  • Advanced analytical options including EDS, ToF-SIMS and EBSD

AMBER X2 brings plasma FIB speed to demanding life science studies, from large-volume 3D analysis to delicate cryo sample preparation. Its stable beam performance helps you obtain clean, artifact-free results across biological interfaces, mineralized tissues and complex structural hierarchies.

Unlocked content

 

OUTPUT EXAMPLES

Unlock
Tescan insight

leave a contact to access

Get the most out of Tescan

This is more than information; it's an advantage. We've compiled our technical whitepapers, detailed product flyers, and on-demand webinars to provide you with the knowledge that makes a real difference. Sign up now to access the insights you need to make an impact.

Tescan AMBER X2

Technical specification

Tescan AMBER X2 FIB-SEM

SEM Column
BrightBeam™ field-free UHR-SEM (Schottky emitter)
  • Imaging Resolution:  0.9 keV @ 15keV, 1.4 nm @ 1keV
  • Beam Current Range: 2 pA – 400 nA
  • Energy Range: 50 eV – 30 keV
  • Low Vacuum Mode: optional, up to 500 Pa
FIB Column
Mistral™ Plasma FIB (Xe+ plasma source )
  • 10 nm @ 30keV, 200 nm @ 1keV
  • FIB Current range: 1 pA – 3.3 µA
  • Energy Range: 500 eV – 30 keV
Specimen Stage
  • Type: 5-axis motorized compucentric stage
  • XY travel range: 130 mm
  • Z range: 96 mm
  • Tilt range: -70° to +90°
  • Rotation: 360°
Detection System
Multiple detection modalities with up-to 8 simultaneous imaging channels

Tescan AMBER X2 FIB-SEM

SEM Column
BrightBeam™ field-free UHR-SEM (Schottky emitter)
  • Imaging Resolution:  0.9 keV @ 15keV, 1.4 nm @ 1keV
  • Beam Current Range: 2 pA – 400 nA
  • Energy Range: 50 eV – 30 keV
  • Low Vacuum Mode: optional, up to 500 Pa
FIB Column
Mistral™ Plasma FIB (Xe+ plasma source )
  • 10 nm @ 30keV, 200 nm @ 1keV
  • FIB Current range: 1 pA – 3.3 µA
  • Energy Range: 500 eV – 30 keV
Specimen Stage
  • Type: 5-axis motorized compucentric stage
  • XY travel range: 130 mm
  • Z range: 96 mm
  • Tilt range: -70° to +90°
  • Rotation: 360°
Detection System
Multiple detection modalities with up-to 8 simultaneous imaging channels
AMBER X 2-1

GET IN Touch

with specialist

map

Where can you find us: 

Tescan
Libušina třída 21
623 00 Brno
Czech Republic

130405923 us US 37.09024 -95.712891 25.3575 29.349345 20.67957527 42.082797 39.91384763 -33.693421 13.93320106 3.039986586 31.997988 38.050985 47.579533 48.1485965 58.375799 54.663142 19.195447 56.975106 50.493053 45.868592 10.79556993 44.35660598 43.2371604 55.536415 14.557577179752773 32.100937 -6.116829 -6.212299277967318 23.7104 -33.471062 31.998740087 -23.69149395 43.462349 51.529848 49.1893523 49.197486 25.072375 31.075811 1.299027 40.676979 52.30150662 51.013813 35.684121 37.479653 52.246622 40.581349 39.911632 -26.1811371 41.818215 33.429928

No distributors found.