A microscopy result is not defined by a solution performance number, but by whether it solves the challenge you are facing better. That is where Tescan focused its 2026 innovations: Reaching deeply buried defects faster through connected X-ray, laser, and FIB-SEM workflows; Producing consistent TEM specimens that preserve the information researchers need; Revealing more information from complex samples; and bringing crystallographic insight into the SEM for earlier, more confident decisions.
Tescan FemtoChisel™ received a2026 Microscopy Innovation Award for its femtosecond-laser sample preparation capabilities. It has also been named a finalist in the Lasers category of the 2027 SPIE Prism Awards, recognizing its contributions to laser-based sample preparation and semiconductor failure analysis. Conventional femtosecond-laser processing leaves a thick heat-affected zone and laser-induced damage. FemtoChisel™ combines high-fluence, targeted material removal with intelligent laser processing to maintain clean surfaces with minimal scratching, enabling rapid access to deeply buried regions of interest in complex multi-material samples.
In an advanced packaging study, X-ray CT located a hidden feature before controlled laser processing created a path to it. Microscopy checkpoints preserved spatial context throughout the material removal process. The workflow demonstrated how precise localization and rapid access can expose deeply buried targets without losing sight of the region of interest.
Figure 1. Comparison of laser cross-sectioning approaches for an Intel 14 nm Kaby Lake-R BGA chip. Left: conventional laser processing without Intelligent Gas Processing or LPL. Right: Tescan FemtoChisel™ with Intelligent Gas Processing and LPL, revealing subsurface structures directly in the laser-milled cross-section.
Learn more: Explore how Micro-CT, laser processing and FIB-SEM work together for advanced packaging failure analysis.
TEM lamella preparation is complex, time-consuming, and highly dependent on operator expertise-often limiting throughput and consistency. Tescan addressed this by combining the faster, more precise Orage™ 2 Ga⁺ FIB column with AI-assisted TEM AutoPrep™ Pro, which automates the workflow from navigation and deposition through lift-out, thinning, and low-energy polishing.
In a 2026 application study, multiple lamellae were processed in a single unattended overnight run. Under optimized test conditions, preparation time per lamella decreased by up to 40% compared with the conventional Ga⁺ FIB approach, while delivering comparable or improved quality.
The value goes beyond speed: repeatable, unattended preparation reduces operator-dependent variation, extends productive instrument time beyond working hours, and frees specialists to focus on challenging samples and data interpretation.
Learn more: Discover why TEM lamella automation alone is not enough and how final specimen quality affects analysis.
Even the thinnest TEM lamella can retain Ga⁺ implantation damage, excessive amorphization, and contamination that obscure its true structure. Conventional final polishing in a separate Ar⁺ tool is a proven solution, but adds handling time and risks damage, misalignment, oxidation, or sample loss during the transfer.
Aura™ Gentle Ion Beam solves this as it is integrated directly inside the Tescan FIB-SEM chamber. Its recipe-based, low-energy Ar⁺ polishing—down to 200 eV- removes preparation-affected surface layers without another transfer. Through this, researchers gain cleaner, nearly ion-damage-free specimens, immediate STEM-in-SEM quality verification, and greater confidence in subsequent high-resolution S/TEM results.
Figure 2: Al₂O₃ TEM specimen before and after final Ar⁺ cleaning. Left: specimen prepared by Ga+ FIB-SEM. Right: the same specimen after Aura™ Gentle Ion Beam cleaning.
Learn more: See how gentle argon ion polishing helps reduce FIB-induced damage during TEM sample preparation
Nanoscale characterization often faces a number of challenges: Magnetic, non-conductive, or beam-sensitive samples need gentle imaging, and subtle surface, compositional, and near-surface differences require multiple contrasts, leading to repeated scans that can damage the sample. The new-generation Tescan CLARA™ addressed both. It provides field-free ultra-high-resolution imaging at low landing energies and unique SE and BSE detection. Using this, researchers preserve the surface of sensitive samples and extract richer information from the same region of interest without rescanning, using a unique combination of energy-filtered and angularly filtered detection systems.
A second challenge was obtaining initial crystallographic insights, which are typically provided only by a dedicated S/TEM. This adds delay, handling risk, and costly instrument time. Tescan’s fully integrated, retractable 4D-STEM detector brings diffraction into selected SEM and FIB-SEM platforms and enables recording of diffraction patterns at every scan position.
Researchers can now map crystal orientation, phases, and grain structure directly in the SEM, create application-specific contrast with virtual apertures, and reprocess datasets without reanalysis of the samples. At the same time, in FIB-SEM workflows, they can verify lamella crystallinity and readiness before transfer - enabling earlier decisions, less rework, and better use of premium TEM time.
Together, CLARA™ and integrated 4D-STEM extend the SEM from high-resolution imaging to multimodal nanoscale characterization. Tescan has provided insights that would otherwise require additional scans, more sample handling, or multiple instruments, thereby shortening the path from observation to a confident decision.
Figure 4: 4D-STEM in SEM: Multiple reconstructions from a single 4D-STEM acquisition. Virtual STEM images reconstructed from angular bands. One dataset delivers multiple contrasts, allowing the virtual aperture to be selected after acquisition.
Written by Petr Klimek, PhD.
Product Marketing Director, Tescan